Quantity: | |
---|---|
The higher the COP the cheaper a heat pump is to run. In comparison to other forms of heating, Heat Pumps offer the most energy efficient heating with between 300% to 400% efficiency.Double compressors system,hot water output could reach 95C;
2.Safe and Security
It use totally isolated electricity and water system to guaranty a security daily use.
3. 4 Season fuction
Various air source heat pump can work under wide ambient temperature ranges, EVI can work well from -25C to 43C, and ground/water source heat pump even has no area limitation,
4. Intelligent control system, complete protection and auto-defrosting system, anti-freeze,
intelligent auto-defrosting system, it assures the heat pump unit can work smoothly under severe cold environment.
5. LCD display friendly interface, It is very convenient and easy to operate by push switch from heating to cooling or hot water in an instant, next a few months, the computer system can remote control the heat pump system.
6. stability,Reliability, Well selected top-brand components to provide you the reliability and most stable performance;
7.No contamination, no carbon emission and to improve air quality.
8.Eco-friendly, With the green refrigerant R407c/R410a, no harm to the ozone,
9.economic, optimized cost saving heat pump for commercial center, hotel, resorts.Two function in 1, heating and cooling function saves the investment cost.
10. operating ambient temperature ranges from -35ºC to 43ºC.
Model No | MG-03FD/HT | MG-05FD/HT | MG-07FD/HT | MG-10FD/HT | MG-13FD/HT | MG-20FD/HT | MG-25FD/HT |
HP | 3HP | 5HP | 7HP | 10HP | 13HP | 20HP | 25HP |
Rated Cooling capacity(KW) | 15.48 | 22.32 | 30.24 | 40.68 | 46.8 | 63 | 78.48 |
Rated heating capacity(KW) | 18.9 | 26.46 | 37.8 | 48.72 | 56.28 | 74.76 | 93.66 |
Rated Cooling input power(KW) | 5.16 | 7.44 | 10.08 | 13.56 | 15.6 | 21 | 26.16 |
Rated Cooling current(A) | 9.77 | 14.09 | 19.09 | 25.68 | 29.55 | 39.77 | 49.55 |
Rated heating input power(KW) | 6.3 | 8.82 | 12.6 | 16.24 | 18.76 | 24.92 | 31.22 |
Rated heating current(A) | 11.93 | 16.7 | 23.86 | 30.76 | 35.53 | 47.2 | 59.13 |
Voltge V | 380V-50hz/60Hz | ||||||
Refrigerant | Mixed refrigerant | ||||||
Refrigerant charge capacity (kg) | 1.8kg | 2 kgs | 2 kgs | 4.4 kgs | 5 kgs | 10 kgs | 12kgs |
0ºC heating capacity(kw) | 17.01 | 21.17 | 30.24 | 38.98 | 45.02 | 59.81 | 74.93 |
.-8ºC heating capacity(kw) | 15.12 | 19.85 | 28.35 | 36.54 | 42.21 | 56.07 | 70.25 |
.-12ºC heating capacity(kw) | 14.18 | 19.85 | 28.35 | 36.54 | 42.21 | 56.07 | 70.25 |
.-18ºC heating capacity(kw) | 12.66 | 17..73 | 25.33 | 32.64 | 37.71 | 50.09 | 62.75 |
Evaporimeter | Internal screw pipe+Hydrophilic corrugated aluminum sheet | ||||||
Max outlet water tempºC | 90ºC | ||||||
Size of pipe | DN25 | DN32 | DN40 | ||||
Size of unit | 820*820*1035mm | 1225*900*1140mm | 1210*1080*2000mm | 2420*1080*2000mm | |||
Weigh | 270 | 345 | 570 | 670 | 710 | 1300 | 1450 |
Working condtiion: | |||||||
1.Hot water condition parameters is in the ambient temperature of 20 degrees, the water temperature from 15 degrees to 95 degrees. | |||||||
2.The cooling condition parameters is in inlet water 12 degrees, Outlet water temperature is 7 degrees, the outdoor environment temperature is 35 degrees. | |||||||
3.The heating condition parameters is in inlet water 75 degree,outlet water temperature 80 degree,the outdoor environment temperature is 7 degrees. | |||||||
The higher the COP the cheaper a heat pump is to run. In comparison to other forms of heating, Heat Pumps offer the most energy efficient heating with between 300% to 400% efficiency.Double compressors system,hot water output could reach 95C;
2.Safe and Security
It use totally isolated electricity and water system to guaranty a security daily use.
3. 4 Season fuction
Various air source heat pump can work under wide ambient temperature ranges, EVI can work well from -25C to 43C, and ground/water source heat pump even has no area limitation,
4. Intelligent control system, complete protection and auto-defrosting system, anti-freeze,
intelligent auto-defrosting system, it assures the heat pump unit can work smoothly under severe cold environment.
5. LCD display friendly interface, It is very convenient and easy to operate by push switch from heating to cooling or hot water in an instant, next a few months, the computer system can remote control the heat pump system.
6. stability,Reliability, Well selected top-brand components to provide you the reliability and most stable performance;
7.No contamination, no carbon emission and to improve air quality.
8.Eco-friendly, With the green refrigerant R407c/R410a, no harm to the ozone,
9.economic, optimized cost saving heat pump for commercial center, hotel, resorts.Two function in 1, heating and cooling function saves the investment cost.
10. operating ambient temperature ranges from -35ºC to 43ºC.
Model No | MG-03FD/HT | MG-05FD/HT | MG-07FD/HT | MG-10FD/HT | MG-13FD/HT | MG-20FD/HT | MG-25FD/HT |
HP | 3HP | 5HP | 7HP | 10HP | 13HP | 20HP | 25HP |
Rated Cooling capacity(KW) | 15.48 | 22.32 | 30.24 | 40.68 | 46.8 | 63 | 78.48 |
Rated heating capacity(KW) | 18.9 | 26.46 | 37.8 | 48.72 | 56.28 | 74.76 | 93.66 |
Rated Cooling input power(KW) | 5.16 | 7.44 | 10.08 | 13.56 | 15.6 | 21 | 26.16 |
Rated Cooling current(A) | 9.77 | 14.09 | 19.09 | 25.68 | 29.55 | 39.77 | 49.55 |
Rated heating input power(KW) | 6.3 | 8.82 | 12.6 | 16.24 | 18.76 | 24.92 | 31.22 |
Rated heating current(A) | 11.93 | 16.7 | 23.86 | 30.76 | 35.53 | 47.2 | 59.13 |
Voltge V | 380V-50hz/60Hz | ||||||
Refrigerant | Mixed refrigerant | ||||||
Refrigerant charge capacity (kg) | 1.8kg | 2 kgs | 2 kgs | 4.4 kgs | 5 kgs | 10 kgs | 12kgs |
0ºC heating capacity(kw) | 17.01 | 21.17 | 30.24 | 38.98 | 45.02 | 59.81 | 74.93 |
.-8ºC heating capacity(kw) | 15.12 | 19.85 | 28.35 | 36.54 | 42.21 | 56.07 | 70.25 |
.-12ºC heating capacity(kw) | 14.18 | 19.85 | 28.35 | 36.54 | 42.21 | 56.07 | 70.25 |
.-18ºC heating capacity(kw) | 12.66 | 17..73 | 25.33 | 32.64 | 37.71 | 50.09 | 62.75 |
Evaporimeter | Internal screw pipe+Hydrophilic corrugated aluminum sheet | ||||||
Max outlet water tempºC | 90ºC | ||||||
Size of pipe | DN25 | DN32 | DN40 | ||||
Size of unit | 820*820*1035mm | 1225*900*1140mm | 1210*1080*2000mm | 2420*1080*2000mm | |||
Weigh | 270 | 345 | 570 | 670 | 710 | 1300 | 1450 |
Working condtiion: | |||||||
1.Hot water condition parameters is in the ambient temperature of 20 degrees, the water temperature from 15 degrees to 95 degrees. | |||||||
2.The cooling condition parameters is in inlet water 12 degrees, Outlet water temperature is 7 degrees, the outdoor environment temperature is 35 degrees. | |||||||
3.The heating condition parameters is in inlet water 75 degree,outlet water temperature 80 degree,the outdoor environment temperature is 7 degrees. | |||||||